002 Hot Air Burners are used on steel reheat furnaces, glass melters, non-ferrous melters, rotary calciners, and other
applications where low velocity luminous flames are desired. They use combustion air at temperatures up to 600oC.
They burn gasesof 2000kcal/scf or higher and light or heavy fuel oils.
GAS AS A FUEL
002 Burners provide soft luminous flames when burning natural
or coke oven gas in large open furnaces, such as slab or billet
heaters. Flame shapes depend on forward velocity of the burning gases. Although rated nominally at 4.5"wc (550°C) air, flames tend
to develop full length at combustion air pressures of 2-3" wc at the
burner.
Gas flames are stable when starting with ambient temperature
combustion air in cold, tight chambers; but well defined flame
shapes may not develop until air is over 200oC. For stoichiometric
firing, required natural gas pressure at the burner varies from
approximately 60% of main air pressure with 10OC air to
approximately 25% of air pressure with 550oC air. Retract the oil
atomizer during gasoperation.
|
OIL AS A FUEL
Standard 002 Burners use high pressure "tip emulsion" atomizers
with 5 to 6 kg/cm2 steam or compressed air. Resultant clean,
highly luminous, well-defined flames are slightly shorter than
natural gas flames. Heavy oils (#4 through #6) must be heated to
reduce viscosity to 100 SSU or less at the burner.
This atomizer is highly efficient, consuming less than one pound of 5 kg/cm2 steam, or 20 ft3 of 80 psi air of #6 oil
burned. (Lower firing rates reduce this efficiency somewhat.) A reliable lowpressure atomizer, using 40- 0”wg cold
air supplied by a turbo blower, is vailable for most grades of oil when steam or compressed air is unavailable.
|
CONTROLSYSTEMS
002 Burners operate from0.2"wc main air pressureto 10"wcor higher. High fire air rate usually is between 2"wc and 6"wc. Input and air/fuel ratio controls should be selected and engineered for the range ability required. If combustion air temperatures vary considerably during normal operating cycles, metered flow control with air temperature compensation is recommended.When combustion air can be metered on the cold side of the recuperator, it may be acceptable to use differential pressure balanced ratio regulator. However, recuperator leakage can cause significant distortions and variations in air/fuel ratio when "cold lead metering" is used. Axis Thermal field engineers are qualifiedt or ecommend the system most suitable for each application.
IGNITION AND FLAME SUPERVISION
A Pilot assembly is normally used to light the burner. Ignition sequence should provide for low fire start between 0.2 and 1.0"wc main air pressure. Pilot mixture pressure should be 3"wc or more. The Honeywell UV detector has been tested on 002 Burners.
002CAPACITY–WITHATOMIZER |
| Burner Size |
Main Air, scfh 550o C air at 4.5"wc AP |
Oil,l/hr based 1400ft 3 air for each oil |
Steamat 5kg/cm2 |
Atom. Sir,scgm at 5kg/cmi(Oil
Flow
rate) |
(No Oil) |
| Atomizer Designation |
(Oil Flow rate) |
(No Oil) |
| -8A |
19000 scfh |
A56 lt/hr |
002-01 |
50.6
kg/hr |
0.902
kg/lt |
22
kg/lt |
7.7
scfm |
13.3
scfm |
| -9A |
32200 |
A23 |
002-01 |
41.8 |
0.45 |
22 |
6.3 |
13.3 |
| -10AA |
40000 |
A29 |
002-01 |
37.4 |
0.32 |
22 |
5.7 |
13.3 |
| -11AA |
53000 |
A38 |
002-01 |
33.0 |
0.21 |
22 |
5.0 |
13.3 |
| -12A |
78000 |
A56 |
002-1 |
176.0 |
0.78 |
77 |
26.7 |
46.7 |
| -14A |
106000 |
A76 |
002-0 |
167.2 |
0.55 |
140 |
25.3 |
46.7 |
| -16A |
134000 |
A96 |
002-0 |
143.0 |
0.37 |
140 |
21.7 |
46.7 |
| -18A |
172000 |
A123 |
002-1 |
396.0 |
0.80 |
225 |
60.0 |
75.0 |
| -20A |
215000 |
A154 |
002-1 |
352.0 |
0.57 |
225 |
53.3 |
75.0 |
| -22A |
260000 |
A186 |
002-1 |
330.0 |
0.44 |
225 |
50.0 |
75.0 |
| -24A |
310000 |
A221 |
002-3 |
1210.0 |
1.36 |
680 |
183.0 |
220.0 |
|